| BROWSE BY PRODUCTS |
|
|
 |
|
|
Unshielded Cables
At Rajsav India Private Limited, we are manufacturing a wide range of Instrumentation Cable used for electronic Control Panel , Control Instruments, Computing Systems and Networking of Instruments. Also designing and developing the Cable as per the custom designed parameters based on national & international standards.

Construction of Cables
- CONDUCTOR: Solid / bunched / stranded copper bare / tinned from 0.25 mm2 to 1.5 mm2.
- INSULATION: PVC / polyethylene / polypropylene extruded cores identified by colours / number printing.
- FORMATION: 1/2/3/4 core are twisted to form singles / pairs / triads.
- INDIVIDUAL SCREENING: Pair / triads are screened by copper wire / shielded by aluminum mylor tape with drain wire.
- ASSEMBLY: Singles / pairs / triads are laid up.
- FINAL SCREENING / SHIELDING: Laid up cable is finally screened by copper wires / shielded by aluminium mylor tape with drain wire.
- ARMOURING: Galvanized steel wire / strips are used.
- SHEATHING: An extruded layer of PVC is applied in different colours as required.
RAYHON® Unshielded Instrumentation Cable
Wide range of Unshielded Multicore/Pair overall polyester tapped tinned/ Bare Copper having different sizes of 7/0.15, 14/0.15, 16/0.20 and 24/0.20 Cable with overall PVC sheath Black & Grey in colours.
Nominal overall diameter in mm
| No. of Core |
7/0.15mm |
14/0.15 mm |
16/0.20 mm |
24/0.20 mm |
| 3 |
4.05 |
4.90 |
5.70 |
6.50 |
| 4 |
4.40 |
5.20 |
6.20 |
7.10 |
| 6 |
4.90 |
6.00 |
7.20 |
8.20 |
| 8 |
5.40 |
6.50 |
7.90 |
9.30 |
| 10 |
6.10 |
7.40 |
8.80 |
10.10 |
| 12 |
6.60 |
8.90 |
9.40 |
10.80 |
RAYHON® Shielded Instrumentation Cable
A wide range of multicore/pair aluminum mylor tapped shilelded with Tinned Copper wire braided overall PVC sheathed Cable having the conductor size of 7/0.15, 14/0.15, 16/0.20 and 24/0.20 are used for data signalling and interconnection from one point to the equipment.
Nominal overall diameter in mm
| No. of Core |
7/0.15 mm |
14/0.15 mm |
16/0.20 mm |
24/0.20 mm |
| 3 |
4.40 |
5.50 |
6.30 |
7.30 |
| 4 |
4.90 |
5.80 |
6.80 |
7.90 |
| 6 |
5.40 |
6.60 |
7.75 |
8.80 |
| 8 |
6.00 |
7.30 |
8.45 |
9.80 |
| 10 |
6.60 |
8.15 |
9.45 |
10.80 |
| 12 |
7.10 |
8.70 |
10.00 |
11.50 |
D.C. Resistance per Km. at 20 C max.
| 162.8 Ohms |
81.4 Ohms |
40.1 Ohms |
26.7 Ohms |
2.Standard Specifications
BS 5308, VED 0815 or any other national / international standard / as per designed based on customer’s requirements.
3. Applications
These cables are widely used for electronic control panels, computing systems and control instruments |
|
|
telephone cords, cctv cables, shielded cables, unshielded cables, cat6 cables, cat5 cables, house wiring cables, instrumentation cables